Fire stopping in Whitechapel

A shop on the ground floor, flats above. The floor between them carries a lot of holes.

  • Every seal labelled and photographed
  • BM TRADA / FIRAS-certificated contractors
  • Written price before any work
Get a price

We reply with a written price.

We use these details to reply to you. See our privacy notice.

Walk down Whitechapel Road or any of the streets off it and you will see the same layout again and again: a shop, café or takeaway at street level and flats on the floors above. The floor between the shop and the first flat is the most important fire separation in the building. It is also the one that services cross most.

Cable trays, a red pipe and purple data cables running through a ceiling void under a concrete slab
Cable trays, a red pipe and purple data cables running through a ceiling void under a concrete slab

What crosses that floor

Kitchen extract ducts from takeaways, rising through the flats to the roof. Drainage from the flats coming down into the shop ceiling. Electric and gas supplies to the flats, which often enter through the shop. Alarm and CCTV cables added by the shop tenant. Every one of those makes a hole, and the shop ceiling usually hides all of them.

Kitchen extract ducts

A duct carrying hot greasy air from a commercial kitchen up through a building of flats is a serious fire risk in itself. Where it passes through floors and walls it needs protecting along its route, not only a seal at the hole. That is specialist duct work and we flag it to you when we see it. What we do handle is the gap round the outside of the enclosure where it meets each floor.

Example: a shop ceiling

Picture a shop with a suspended ceiling and lift two tiles at the back. Above them there might be a 110mm soil pipe from the flat upstairs with no seal round it, a cluster of cables going up through a ragged hole about 150mm across, a copper gas pipe in a sleeve with an open gap round the outside of the sleeve, and the extract enclosure in the corner with a 30mm gap along its base.

On the record that ceiling turns into four seals. The soil pipe gets a collar under the floor. The cable hole is closed with batt and mastic. The gas sleeve is sealed round its outside, with the gas pipe itself left alone, and the base of the extract enclosure is sealed to the floor. The landlord also gets a note that the duct inside the enclosure should be looked at by a kitchen extract specialist, since that is not fire stopping work.

Fire stopping in Whitechapel is carried out by our BM TRADA / FIRAS-certificated contractors.

Got a survey that lists open penetrations?

Send us the page that lists them, or a few photos with a tape measure in shot, and the postcode. We come back with a written price.